Rectify malfunctions
Malfunction
Incorrect flushes (too soon,
too late, unwanted)
Water is running
continuously into the urinal
ceramic
Flushing out of the urinal
ceramic is inadequate
Decrease in flush volume
Battery warning level 1
4 short signal tones upon
entering the detection
range
Battery warning level 2
No flush actuation, 2 short
signal tones every 30
seconds
Battery warning level 3
No flush actuation, no signal
tone
16
Cause
Detection distance not set
correctly
IR window is dirty or wet
IR window scratched
Software fault
Technical fault
Flush time set incorrectly
Basket filter in solenoid
valve blocked
Battery dead/rechargeable
battery empty
Rectification
Optimise the detection
distance, see "Maintenance"
Clean or dry the window
Contact a skilled person
Restart the urinal flush
control, see "Maintenance"
Contact a skilled person
Set flush time, see
"Maintenance"
Clean the basket filter, see
"Maintenance"
Replace the batteries/charge
the rechargeable battery of
the self-sustaining power
supply, see "Maintenance"