EN
Replace the trap
For hygiene reasons, replace the trap at
least once a year.
Prerequisite
Cleaning mode is activated.
Replace the trap.
1
Remove the trap.
2
Replace the trap and cover (art. no.
243.312.00.1 and 243.314.00.1).
3
Install the trap.
Clean or replace the basket
filter
Clean the basket filter in the solenoid valve
at least every 2 years or if the flush volume
decreases. Descale the basket filter with a
commercially available descaling agent if
necessary. Replace the basket filter if it can
no longer be completely cleaned and
descaled.
Remove the urinal flush control.
1
Open the protection flap and remove
the urinal flush control.
2
Disconnect the cable for the battery
or rechargeable battery
compartment.
18
Clean or replace the basket filter.
3
Remove the basket filter.
4
Clean, descale or replace the basket
filter.
5
Install the basket filter.
Install the urinal flush control.
6
Plug in the cable for the battery or
rechargeable battery compartment.
7
Insert the urinal flush control and
close the protection flap.
Result
The urinal is once more ready for
operation.
Set the flush time
Deactivate the urinal flush control.
1
Open the protection flap and remove
the urinal flush control.
2
Disconnect the cable for the battery
or rechargeable battery
compartment.
Restart the urinal flush control.
3
Plug in the cable for the battery or
rechargeable battery compartment.