G CORRECTING ROOM TEMPERATURE MEASUREMENT
This allows the user to correct the room temperature detected by the control unit and adapt it to different
user needs.
The entire correction procedure must be done with the control unit powered and connected to the boiler.
Room temperature correction:
Press key R and keep it pressed:
Press the
key.
Release key R and wait until the display shows the confirmation message "Son"
The next two stages must be done within 5 seconds otherwise the procedure will be aborted.
Release the
Press the + key to introduce a positive correction (an increase of one unit means an increase of 0.1°C).
Press the - key to introduce a negative correction (a decrease of one unit means a decrease of 0.1°C).
Wait 5 seconds after the last modification to exit this function and recommence normal operation.
G TEMPERATURE CONTROL: SELCTING THE FUNCTION MODE.
These procedures allow the user to select one of the three possible temperature control modes.
The entire procedure must be done with the control unit powered and connected to the boiler.
Choosing a temperature control function mode:
Press key R and keep it pressed:
Press the
key.
Release key R and wait for the display to show the present temperature regulator mode (tdi, ton or trc).
The next two stages must be done within 5 seconds otherwise the procedure will be aborted.
Release the
key.
Press the
key to disable the temperature regulator, press
or press
to select modulating regulator mode.
The display will then show the tdi, ton or trc confirmation message.
Wait 5 seconds after the last modification to exit this function and recommence normal operation.
key.
to select ON - OFF regulator mode
55