9

DISASSEMBLY AND DISPOSAL

9
Disassembly and disposal
10

Maintenance

14
LED indicator/fault pattern
Green LED flashes
Switching outputs do not
behave in accordance with
table 5
Yellow LED flashes
Signal interruptions when
object is detected
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
This symbol on the product, its package or in this document, indicates
that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Cause
Sensor is faulty
IO-Link communication
IO-Link communication
Change of the configuration
Short-circuit
Distance between sensor and
reflector is too large / light
beam is not completely
aligned to the reflector /
reflector is not suitable/Front
screen and/or reflector is con‐
taminated.
Depolarizing property of the
object surface (e.g., tape),
reflection
Measures
If the power supply is OK,
replace the sensor
-
None
Adjustment of the configura‐
tion
Check electrical connections
Check the operating condi‐
tions: Fully align the beam of
light (light spot) with the
reflector. / Clean the optical
surfaces (sensor and reflec‐
tor). / Reflector is not suitable
for the application in question
(we recommend only using
SICK reflectors) / Check sens‐
ing range and adjust if neces‐
sary
Reduce sensitivity or change
the position of the sensor
8022198 | SICK
Subject to change without notice

Publicidad