1. Electrical connection

Electrostatical discharges can
lead to damages of electronic
components!
Please note: components are
carrying high voltages!
1.1 Overview of the electrical connections
sensor ground collective terminal strip
| 20
Vor Öffnen Gerät spannungslos
schalten!
-
!
Isolate mains before removing
clamp-cover!
Masse-Sammelklemme benutzen
Use the Ground Collective Terminal Block
Sensors
Bus
VBus
sensor clamps
VBus
®
The SOLEX is already wired. Points 2.1 - 2.5 are
only for information.
The connection to the power supply system (230 V/AC,
50 ... 60 Hz) is effected by the already clamped line con-
nector. Workings on the current-carrying components of
the FriWa-module must only be carried out by a specialist
firm regarding current standards and corresponding norms
(VDE 0100,VDE 0185,VDE 0190 etc.).
An appropriate earthing is to be carried out at the holding
plate of the SOLEX!
Nullleiter-Sammelklemme
benutzen!
N
Use Neutral Conductor
Collective Block
Schutzleiter-Sammelklemme
benutzen
Use PE Collective Block
+
OK / Set
T4A
floating relay
electro-
mech.
conductor
2 (1)
2 (1)
1 (1)
~
~
250 V
250 V
250 V
consumer clamps
L'
L N
semi-
~
fuse T4 A
net clamps
neutral-
terminal strip
ground wire -
terminal strip