Requirement:
„ Device is installed correctly.
„ Device is in a proper condition.
„ The necessary fusing devices (residual current device,
circuit breaker) are integrated into the house installa-
tion in compliance with the respective national regula-
tions, functional and switched on.
Î "5.3.3 Providing fuse protection"
„ During the initial setting-up process, the device was
inspected in accordance with IEC 60364-6 and the
applicable national regulations (e.g. in Germany: DIN
VDE 0100-600).
Î "6.3 Testing the device"
9
LED "Standby" is illuminated on the LED information
panel.

6.3 Testing the device

Test according to IEC 60364-6 and the applicable
national regulations (e.g. in Germany: DIN VDE 0100-
600)
Prior to the initial commissioning, execute a test of the
device in accordance with IEC 60364-6 and the appli-
cable national regulations (e.g. DIN VDE 0100-600 in
Germany). The test can be carried out in connection with
the MENNEKES test box and standard-compliant test
equipment. The MENNEKES test box simulates vehicle
communication. Test boxes are available as an accessory
from MENNEKES.
f Perform a standard test before releasing the device.
Operating instructions of the test box.


6.4 Closing the device

1
Fig. 10: Closing the device
f Open the top section of housing (1) upward.
f Screw the top and bottom housing sections together.
Tightening torque 1.2 Nm.
EN
17