4. Technical data

Charging power Mode 3 [kW] *
Rated voltage U
[V] AC ±10 %
N
Rated frequency f
[Hz]
N
Rated current I
[A]
nA
Maximum backup fuse [A]
Protection degree
Protection class
Dimensions H x W x D [mm]
Weight [kg]
Rated insulation voltage U
Rated impulse withstand voltage U
Rated current of charging point circuit I
Rated conditional short-circuit current of charging points
circuit I
[kA]
cc
Rated diversity factor RDF
Pollution degree
Overvoltage category
Types of system earthing
Installation
Stationary or movable
Usage
External design
EMC classification
Mechanical impact protection
Terminals for supply
line
External switching con-
tact terminal strip
Standard
* The device can be operated in single-phase or three-phase.
[V]
i
[kV]
imp
[A]
nC
Terminals [mm²]
Clamping range [mm²]
Tightening torque [Nm]
Clamping range [mm²]
Tightening torque [Nm]
®
AMTRON
Compact 3.7 / 11 C2
3.7 / 11
230 / 400
50
up to 16
According to name plate / configuration
IP 44
I
361 × 207 × 146
4.7
500
4
16, 1 ph / 3 ph
10
1
3
III
TN / TT (IT only under certain conditions
see "5.6.1 Power supply")
Outdoor or indoor
Stationary
AEVCS
Wall mounted
B
IK10
6
rigid 5 x 6
flexible 5 x 4
max. 1
rigid 5 x 6
flexible 5 x 4
max. 1
EN 61851, DIN IEC / TS 61439-7
EN
9

Publicidad