Maintenance intervals
The tasks described below may only be carried
out by a qualified electrician.
Select the maintenance intervals with due consideration
of the following aspects:
„ Age and condition of the device
„ Environmental influences
„ Mechanical stress
„ Last test reports
Perform maintenance at least in the following intervals:
Component
Every 6 months
Electrical
Check residual current circuit break-
Switching and
ers, circuit breakers, etc. for optical
Safety Devices
defects.
Check residual current circuit breaker
for damage.
Housing exte-
Check device for defects or damage.
rior
Ensure that the device is clean. Clean
if necessary.
Î "8.2 Cleaning"
Charging cable Check charging cable for damage
(e.g. kinks, cracks).
Repetition of measurements and tests
in accordance the applicable national
regulations (e.g. in Germany: DIN VDE
0701/702).
LED informa-
Check LED information panel for
tion panel
correct functioning and readability.
Restart the device (the LEDs light in
sequence during a restart).
Maintenance work
Component
Yearly
Terminals
Check the terminals of the supply line.
If necessary retighten terminals.
Device
Repetition of measurements and tests
according to IEC 60364-6 and the
applicable national regulations (e.g. in
Germany: DIN VDE 0105-100).
f Eliminate damage to the device according to regula-
tions.
f Document maintenance sufficiently.
f If necessary, request a maintenance protocol from
MENNEKES.
Î "1.1 Service"

8.2 Cleaning

T
T
DANGER
Risk of fatalities due to electric shock
The device contains electrical components that carry high
voltage. Improper handling of the opened housing, espe-
cially in connection with moisture, will cause severe injury
to persons due to electric shock.
f Only clean the outside of the device.
f Keep the device and protective equipment closed.
Maintenance work