3-Part Guide Assembly; Single Guide Assembly; Connection Of The Motor Casing To The Steel Guides; Traditional Installation - Key Automation HALO Instrucciones Y Advertencias Para Su Instalación Y Uso

Motorreductor para puertas de garaje
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38

4.2 - 3-part guide assembly

Assemble the guide (FIG. 4) then pull the belt or the chain (FIG. 7)

4.3 - Single guide assembly

Pull the belt or the chain (FIG. 7)

4.4 - Connection of the motor casing to the steel guides

Follow the instructions in section 4.1 (FIG. 13, 14, 16)
4.5 - Installation with motor casing on cross beam
ATTENTION !
For anything not indicated, please refer to paragraph 4.1
4.6 - Standard installation
ATTENTION !
For anything not indicated, please refer to paragraph 4.1
ATTENTION !
DO NOT REMOVE THE REAR COVER!
Fix the bracket to the cross beam (FIG. 26), then connect the steel
guide using one of the two long screws supplied (FIG. 39) and to
follow the instructions of TAB. 1C and TAB. 2.

4.7 - Manual opening of the door

In the event of a power failure and if the optional buffer battery is not available, to unlock the automation system:
PHASE DESCRIPTION
1
Pull the cord in order to bring the release lever to its vertical position (FIG. 30)
2
Lift or lower the door manually
3
To reset the automation system, move the cord so as to allow the release lever to fit fully back into the pulling slider (FIG. 36)
4
Lift or lower the door manually until it engages with the guide
4.8 - Fixing the LED guide opening limit stop
Unlock the slider, manually lift the door until it is in its maximum pos-
sible indicated opening position H - 10 cm (FIG. 44).
Mark the end position of the slider with a pencil (FIG. 45), then drill a
4.9 - Fixing the steel guide opening limit stop
Unlock the slider, manually lift the door until it is in its maximum pos-
sible indicated opening position H - 10 cm (FIG. 44).

4.10 - Electrical wiring

ATTENTION !
Before connecting, check that the control unit is not powered
Follow the connection instructions (FIG. 48)
ELECTRICAL WIRING
COM
FLASH, LED output common
FLASH
Flashing output 24Vdc (not regulated), maximum 3W
LED
Courtesy light output 24Vdc (not regulated), maximum 20W
PH-POW
Photocell power positive output 24Vdc (not regulated), maximum 100mA
NEG
Photocell power negative output
PH
Photocells (closing) NC contact between PH and COM
EDGE/EDGE
Sensitive edge input, NC contact, 8k2 resistive or 8k2 double resistive (parallel)
Follow the instructions in section 4.1 from FIG. 25; please be careful
not to connect the bracket to the slot, but to the single hole (FIG. 38)
and to follow the instructions of TAB. 1B and TAB. 2.
Then continue following the instructions in section 4.1
Raise the guide until parallel to the ground, measure the dimension
A and then cut the two ceiling brackets as shown: dimension A + 3
cm (FIG. 40). Insert the quick coupling plate, then connect it to the
ceiling brackets (FIG. 41, 42).
Fix the brackets to the ceiling using suitable screws and anchors
(not supplied).
Follow the instructions in section 4.1 from FIG. 29 to FIG. 35, by
inserting the arm in the slit of the slider previously cut open with a
utility knife (FIG. 43).
hole and fix with the screw (FIG. 46).
Firmly fasten the limit stops (FIG. 47).
EN
7

Publicidad

Tabla de contenido
loading

Tabla de contenido