Sensing range setting
The teach-turn adjustment is used to set the object mode and switching threshold,
figure
3,
see figure
4.
The WLG16 is equipped with AutoAdapt technology. The switching threshold is automati‐
cally adjusted in the event of contamination or after cleaning.
Turn the press-turn element (without pressing) to set the desired object mode. A blue
LED indicator lights up according to the set object mode.
Press the press-turn element for about 1 to 3 seconds to set the switching threshold.
If mode 1 to 4 is selected, the yellow LED indicator lights up when the reflector is in
view of the sensor.
Lead the object into the path of the beam. The yellow LED indicator goes out, mean‐
ing the object is detected and the setting is correct.
With object selection 5, the film must be in the path of the beam when the poten‐
tiometer is pressed. The yellow LED indicator does not light up until the film is no
longer in the beam path. When this has been checked, the setting is correct.
The blue LED indicator of mode M lights up when a setting has been selected via IO-
Link which deviates from the predefined parameter sets of modes 1-5. This mode
cannot be selected directly on the device.
3
4
5
2
1
M
Highly-transparent objects
1
Semi-transparent objects
2
Opaque objects
3
Bottles/trays
4
Check of foil tear
5
M
Manual (specific setting via IO-Link)
7