CP 0315
If the ambient temperature is below 32 °F (0 °C) the
hose must be short enough to prevent the water
from freezing before reaching the water separator.

Lubrication

The lubricant is important for the machine s function
and has a great impact on the service life. In order
to supply the correct volume of oil, an oiler should
be connected to the air hose. The use of Chicago
Pneumatic air line oiler is recommended. To
guarantee good lubrication, the length of the air
hose between the oiler and the pneumatic tool
should not exceed 10 feet (3 m).
Too much lubrication can cause starting problems,
low power or uneven performance.
Use a synthetic lubricant such as CP Airolene Plus
Tool Oil or mineral oil with the properties
recommended in the table below.
Temperature
Lubricant
range °F (°C)
CP Airolene Plus
-4 to +120
Tool Oil
(-20 to +50)
Air tool oil
-4 to +60
(-20 to +15)
Air tool oil
+60 to +120
(+15 to +50)
It is recommended that the oil contains a
rust-inhibitor.

Drill bit

CAUTION
Hot insertion tool
The tip of the insertion tool can become hot and
sharp when used. Touching it can lead to burns and
cuts.
Never touch a hot or sharp insertion tool.
Wait until the insertion tool has cooled down
before carrying out maintenance work.
NOTICE
Never cool a hot insertion tool in water,
it can result in brittleness and early failure.
Choosing drill bit
A correct drill bit is a condition for good operation.
To avoid unnecessary machine damage, it is
important to choose drill bits with a high quality.
Fitting and removing the drill bit
To prevent an accidental start: switch off the air
supply, bleed the machine by pressing the start and
stop device and disconnect the machine from the
power source.
9800 0554 90b | Original instructions
Screw the core drill onto the water swivel (½" BSP
thread). Lock the spindle using a 1" open spanner
and tighten the core drill.

Operation

Viscosity
-
Involuntary start of the machine may cause injury.
100-150 SUS
(ISO VG 22-32)
225-350 SUS
(ISO VG 46-68)
Safety and operating instructions
WARNING
Involuntary start
Keep your hands away from the start and stop
device until you are ready to start the machine.
Learn how the machine is switched off in the event
of an emergency.
Stop the machine immediately in all cases of
power supply interruption.
13