Recommissioning
1. Remove the spark plug.
2. Quickly pull the starter cord to remove leftover oil from
the combustion chamber.
3. Clean the spark plug and check the spark gap. Re-
place if necessary.
4. Prepare the device for operation.
5. Fill the tank with the correct fuel/oil mixture (50:1).
Troubleshooting
PROBLEM
Engine does not start
Engine starts but does not
continue to run
Engine starts but does not run
with full performance
Motor runs spasmodically
Excessive smoke
In the case of faults that are not listed in this table, or faults that you cannot rectify without assistance, please
contact our customer service department.
474 218 _a
Disposal
POSSIBLE CAUSE
Incorrect starting procedure
Wrong lever position on the choke
Dirty, incorrectly adjusted or wrong
spark plug
Fuel filter clogged
Wrong lever position on the choke
Air filter clogged
Dirty, incorrectly adjusted or wrong
spark plug
Incorrect fuel mixture
Machines that are no longer
required must not be disposed
of with household waste!
Packaging, machine and accessories are manufac-
tured using recyclable materials and must be disposed
of accordingly.
CORRECTION
Observe operating instructions
Set the lever to RUN
Clean, adjust or exchange the spark
plug
Exchange the filter
Set the lever to RUN
Clean or exchange the filter
Clean, adjust or exchange the spark
plug
Use the correct fuel mixture
(ratio 50:1)
GB