Install Finishing Trim; Installing Ductwork - Best D49M30SB Manual Del Usuario

Ventilador de tiro descendente
Ocultar thumbs Ver también para D49M30SB:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installing Finish Trim
15
B
1
CAUTION
Only connect or disconnect UP BUTTON CABLE
with main power off for at least 60 seconds.
Insert wiring harness with wire from right upper button (D) into opening
in side of downdraft (B). Insert upper button (D) wiring harness into
receptacle at lower right side of downdraft (B). Connect ground wire to
ground nut on lower right of downdraft.
16
D
2
Remove tape backing. Wipe surfaces clean on underside of right trim (D)
so that tape adhesive will stick tightly. Press right trim in place.
Note: Make sure trim: sits flat on countertop surface, is flush with top
door, has 1/16 " GAP between trim and top door, and wiring is not pinched.
D
3
TOP VIEW
Washer
1/16" Gap
1/16" Gap
Door
Trim
D
Flush
Installing Finish Trim
17
C
1
Remove tape backing. Wipe underside surface of left trim (C) so that tape
adhesive will stick tightly. Press left trim in place.
Note: Make sure trim sits flat on countertop surface, is flush with top door,
and has 1/16 " GAP between trim and top door.

Installing Ductwork

CAUTION
BEFORE CUTTING HOLE IN CABINET FOR
DUCTWORK, check for interference with floor
joists, wall studs, electrical wiring, or plumbing.
Refer to Ductwork Configurations in the Planning section of this
document.
Cut hole in cabinet as well as holes in wall or floor as necessary.
Mount the roof or wall cap and work back towards the cabinet,
attaching all ductwork, elbows and transitions as previously
planned. Tape all ductwork connections to make them secure and
air tight.
Connect ductwork (and transition, if required) to downdraft.
16
Installation
(continued)
TOP VIEW
2
1/16" Gap
1/16" Gap
Trim
C
Washer
Door
Flush

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

D49m36sbD49m48sb

Tabla de contenido