3. Mounting and setting of dosing
monitor
1. Mount the dosing monitor.
2. DME/S 2 to 48: Connect the dosing monitor, see
fig. A, page 40.
DME 60 to 940: Connect the dosing monitor, see
fig. B, page 41.
3. Activate the monitor input in the "SETUP" menu.
The function can be checked by letting air into the
suction tube. This makes the pump change over to
alarm mode (requires a certain counter pressure).