4 Setting the inverter

This chapter describes how to configure the inverter settings when the ISS 1Play has been
wired to the PYLONTECH US2000/US3000/FORCE-L1/FORCE-L2 batteries.
To do so, once the inverter is supplied by DC (PV or battery) one of the following configurations
must be followed:
4.1

Setting the ISS 1Play TL M

Configure through the Wizard:
This option is given during the commissioning. Access to the board interface of the inverter. Set
the battery type: PYLONTECH US2000/US3000 (also valid for FORCE-L1/FORCE-L2).
Use and settings of the INGECON SUN STORAGE 1Play TL M working with
PYLONTECH US2000/US3000/FORCE-L1/FORCE-L2
Please be careful to choose the right battery type when you set up the
configuration in your inverter. The battery or inverter manufacturers have
no responsibility on the damages caused due to incorrect configurations.
For instance, if you select "Lead-acid" as a battery type in the inverter
configuration and the battery being used is "Lithium-ion", the battery might
get damaged or experience performance degradation.