Appendix A: Installation protocol
Copy the installation protocol, fill it in and save it as a service record.
For values, note the value in the result column, otherwise a tick will suffice if the item has been
performed or considered.
WARNING!
No zone present during installation, service and cleaning.
NOTE! If a value is outside its accepted level, or a result is incorrect or missing, fix the problem
before initial start-up and normal operation.
Unit No.
Control items
APPLICATION REQUIREMENTS LIMITS
Installation Area classification
Zone, dust 21,22
Zone, gas 1,2
Material MIE (>1 mj).
DELIVERY CONTROL
Transport damage.
Missing components.
Maintenance access.
MOUNTING
Bolts and nuts suitable for the wall material.
1100N/2400N/4000N
Extraction arm is fitted in a horizontal
position.
NEX S housing is properly grounded.
Earth continuity < 100 ohm
Risk of personal injury.
Date:
Performed by:
Reference
Result
NEX S
Notes