Oase ProMax Pressure 6000/8 Instrucciones De Uso página 14

Ocultar thumbs Ver también para ProMax Pressure 6000/8:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Horizontal installation of the pump
with the stand
(Only ProMax Pressure 6000)
The pump can be horizontally installed
with the stand in a shallow tank or well.
• The pump has to be aligned exactly hor-
izontally.
• Ensure that the water to be pumped
does not contain any sand.
How to proceed:
 E
1. Remove the Allen screws.
– The stand consists of two sections.
2. Push two mounting feet onto each stand
section.
3. Push three rubber pads each into the
grooves of the opening of the stand sec-
tions.
– Fit rubber pads to both stand sec-
tions.
4. Push both stand sections onto the
pump.
– The stand sections should be spaced
as far apart as possible to ensure the
stability of the pump.
OPERATION
The pump control system (flow control)
measures the flow and switches the pump
off if the water flow stops.
• The pump switches off when there is in-
sufficient water, protecting it from being
damaged by running dry.
• In automatic mode, the pump control
system switches the pump on and off.
14
The integrated non-return valve prevents
water from flowing back into the pump
from the pressure hose when it is switched
off. The non-return valve also prevents
damage to the pump resulting from water
hammer.
Automatic mode
The pump switches off automatically
when no more water is used and the max-
imum pressure in the pressure line is
reached.
The pump switches on automatically
when water is used and the pressure in
the pressure line falls below 3.5 bar.
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
• Only connect the pump to the power
supply when there are no persons in or
reaching into the water.
• Before stepping into or reaching into the
water, switch off all units located in the
water.
Switching on the unit
• Insert the power plug into the socket.
– The pump is ready for operation.
Switching off the unit
• Disconnect the power plug.
– When the pump is switched off, resid-
ual water in the hose may flow back
and out of the pump intake.
ProMax Pressure 6000, Pressure Well 6000

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pressure well 6000/8Promax pressure well automatic 6000/8