- GB -
Replacing the UVC lamp
Replace the UVC lamp after max. 8,000 operating hours (this corresponds to approx. one pond season with continu-
ous operation). This ensures optimum filtering performance.
• Only use UVC lamps whose identification and capacity data correspond to the information on the type plate.
(→ Technische Daten)
Prerequisite: The device head is removed. (→ Removing the unit head)
6.
How to proceed:
0.
N
1. Remove the cleaning rotor.
2. Unscrew the clamping screw counterclockwise.
3. Remove the quartz glass including the O ring towards the front with a slight turning movement.
4. Pull out the UVC lamp and replace.
5. Carefully push the quartz glass including the O ring into the unit head up to the stop, fit the clamping screw and
tighten up to the stop by turning clockwise.
− Clean the O ring, replace if damaged.
− Ensure that the O ring is located in the gap between the unit head and the quartz glass.
6. Push the cleaning rotor onto the quartz glass.
− Ensure that it is correctly positioned.
7. Fit the unit head. (→ Fitting the unit head)
Wear parts
The following components are wear parts and are excluded from the warranty:
• UVC lamp, quartz glass and O ring for quartz glass
• Cleaning rotor
Storage/Over-wintering
The unit is protected from frost:
The unit can be operated as long as the water temperature does not go below +4 °C.
The unit is not protected from frost:
Take the unit out of operation at water temperatures below +8° C or, at the latest, when freezing temperatures are to
be expected.
• Drain the unit as far as possible, clean thoroughly and check for damage.
• Empty all hoses, pipes and connections as far as possible.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Dispose of the UVC lamp by using the return system provided for this purpose.