USING THE COMPRESSED AIR BREATHING APPARATUS
3.9.
Filling with Quick-Fill
Fig. 7
Fill with Quick-Fill (optional)
1
Quick-fill coupling
With the Quick-fill function, the compressed air cylinder(s) of the breathing
apparatus can be filled during use (see Instruction Manual for Quick-Fill).
3.10. Removing the Compressed Air Breathing Apparatus
(1)
Remove lung governed demand valve and .
(2)
Close cylinder valve(s).
(3)
Activate flushing mode of lung governed demand valve, releasing all air
pressure.
(4)
Open hip belt.
(5)
Extend shoulder straps by lifting the slides.
Danger!
Do not throw off compressed air breathing apparatus. This could
damage the valve and any remaining compressed air could escape
suddenly.
This could cause fatal injury to you or to any bystanders.
(6)
Remove compressed air breathing apparatus.
12
AirMaXX SL
1
MSA
GB