3. Pull out the side burner ignition pin wire from
igniter, lift the top panel of the side burner, and
push back the front end of the top panel of the side
burner until you can see the side burner orifice.
(Fig. 7) (Fig. 8)
4. Use a wrench to remove the orifice from the side
burner valve. Then install the NG orifice. (Fig.9)
During this process, hold the panel component,
otherwise, it may drop to cause injury.
Make sure you are using the correct orifice,
marked "1.37".
5. Adjust side burner's air shutter by loosening the air
shutter screw. (Fig.10)
The settings are:
1/2 in. open for LP gas.
3/16 in. - 5/16 in. open for NG gas.
You need to adjust the openings before you put the
burner back in the burner box.
Side burner ignition pin wire
Side burner orifice
Air shutter
24
Fig. 7
Fig. 8
1.37
Fig. 9
Fig. 10