Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Part PJ098:
D45RE8
- 20 GPM
Injection Seal Kit
(For serial numbers up to 07141221)
This kit contains:
(1) P185
Check valve
barb
(1) PJ017
Check valve
assembly
(1) J015
Plunger
seal
(1) J053
Injection
sleeve o-ring
(1) J054
Injection
stem o-ring
(2) J534EP
Black
adaptor seal
Vea el reverso para
instrucciones en Español.
2090 Sunnydale Blvd.
Clearwater, FL 33765
800-523-8499 • 727-443-5404
www.dosatronusa.com
4.
Unscrew locking
nut (P176) and
remove two rings
(P190) and the
dosing sleeve
(P568).
5.
Pull white stem down,
being careful of key
(P180). Remove
and replace top seal
(J053) and stem
o-ring (J054).
6.
Making sure nut
(P178) is on,
slide white stem
in and replace
the key (P180).
Kit Contents:
PJ017: Check
P185:
valve assembly
Check valve
barb
J053: Injection
J015:
sleeve o-ring
Plunger seal
J054:
J534EP:
Injection stem
Black adaptor
o-ring
seal
CAUTION: Parts may contain
STOP
concentrated chemicals. The use of
Proper Protective Equipment is recom-
mended when performing maintenance.
7.
Thread on sleeve
(P568). Reinstall
the two rings
(P190) and locking
nut (P176).
8.
Insert new
check valve
assembly
(PJ017), attach
check valve
barb (P185),
and screw on
check valve nut
(P079).
Do not forget to reset the injector
to the proper percentage.
Instructions
(Parts included in kit noted in blue)
1.
Unscrew
upper black nut
(P178) to remove
injection
assembly.
2.
Remove and replace plunger seal
(J015).
3.
Remove check valve assembly
(PJ017).
Using tools could damage the plunger
and affect the injection rate
To remove o-ring easily without tools,
squeeze it on either side to raise the
seal, then slide it over the groove
Insert injection stem assembly into
9.
lower housing, careful not to pinch top
seal (J053).
10.
Unscrew inlet/outlet adapters (P252).
Remove old black adapter seals
(J534EP) and replace with new ones
from kit. Screw inlet/outlet adapters
(P252) back on.
J534
P252
We recommend cleaning all parts with warm
soapy water and a toothbrush before
installing the new parts.
Water normally lubricates the parts, but you
may use silicone on the o-ring to facilitate
insertion.
Check valve may be taken apart and
cleaned in between maintenance to remove
particles.
J534
P252

Publicidad

loading

Resumen de contenidos para dosatron PJ098

  • Página 1 Instructions (Parts included in kit noted in blue) PJ017: Check P185: Unscrew valve assembly Check valve upper black nut Part PJ098: barb (P178) to remove injection D45RE8 - 20 GPM assembly. Injection Seal Kit (For serial numbers up to 07141221)
  • Página 2 Contenido del Kit: Instrucciones Desatornille la (Partes en color azul están incluídas en el kit) tuerca de seguri- P185: Desatornille la PJ017: Válvula dad (P176), rem- Lengüeta de la tuerca negra en cheque ueva los dos anillos válvula la parte superior (P190) y la manga cheque (P178) para re-...