Troubleshooting
CRX110, CRX140
Number of
Fault
flashes
1
Line Voltage
2
Excessive fan current
3
The motor doesn't start The rotor is jammed.
4
Speed too low
5
Overheating of the
electronics unit
Constantly
Temperatur sensor
errors
32
Possible cause
The supply voltage is outside of the set range.
The fan load on the electronics unit is more
than 1 A.
The pressure difference in the cooling system
is too high (> 5 bar).
If the cooling system is overloaded, the
minimum speed of the motor of 1,850 rpm
cannot be maintained.
If the cooling system is loaded too heavily or
the temperature is set too high, the
electronics can overheat.
Temperatur sensor is defective.
CRX
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Crx 65Crx 80Crx 110Crx 140

Tabla de contenido