limit positions "0" and "1" have not been memorised;
if necessary, cancel them according to procedure 5.9.
- Position "1" must be located a few centimetres be -
yond the mechanical connection stop. During open-
ing. this will enable the canvas to reach first position
"1" and then hook up to the mechanical stop during
ascent.
- Position "S" must be located a few centimetres be -
yond the disconnection mechanism. During closure,
this will enable the canvas to reach first position "S",
automatically detach from the mechanical stop and
then raise to the closing limit position "0".
01. Press and hold the Up button and, when the
awning blocks automatically in position "0", if the
"RDC" function is to be programmed, release the
button and resume the procedure from point 02.
Otherwise, with the Up button still pressed, press
and hold also the Down button until the awning
performs a brief down movement. Then release
the two buttons.
02. Press and hold the Down button, move the
awning beyond the connection point and stop it a
few centimetres after this position (if necessary
correct the position using the two buttons).
03. Press and hold the Up and Down buttons simul-
taneously and wait for the awning to complete
two short movements: one up movement and
(after a few seconds) one down movement, until it
stops again in the set position. Then release the
two buttons.
04. Press and hold both the Up and Down buttons
simultaneously until the awning performs a short
up movement. Then release the two buttons.
05. Use the Up and Down buttons again to move the
awning to disconnect position "S".
06. Press and hold the Up and Down buttons simul-
taneously and wait for the awning to complete
two short movements: one up movement and
(after a few seconds) one down movement, until it
stops again in the set position. Then release the
two buttons.
6 – English
5.8 - Activating the "FTA" function
This function has been developed exclusively for
awnings with a manual mechanism to block the
canvas in the opening position (for example, the
mechanism on rollout and canopy awnings).
If the function is active, during closure the motor is
stopped automatically as soon as the awning comes
into contact with the blocking mechanism on its route.
To then release the awning, press the Down button,
wait for the awning to reach limit position "1", release
the mechanism manually and close the awning by
means of the Up button.
Caution! - The "FTA" function can only be set after
programming the limit position values "0" and "1".
When "FTA" is active, the "RDC" function acts on
the entire travel of the awning.
01. Use the Up or Down button to move the awning
to the point of mid-travel.
02. Press and hold the Up and Down buttons simulta-
neously and wait for the awning to perform a short
movement, a pause and then a second short
movement; then release the buttons.
5.9 - Deleting the entire memory
Caution! - This procedure deletes all data in the
Con trol unit memory, including positions "0" and "1".
01. Use the Up or Down button to move the awning
to the point of mid-travel.
02. Press and hold the Up and Down buttons simulta-
neously and wait for the awning to perform a short
movement, after which release only one of the two
buttons
03. With 3 seconds after the awning has performed
the short movement, press the previously released
button (in point 02) three times.
04. The release the other pushbutton.
Note – If cancellation is completed correctly, on activa-
tion of an up or down command, the awning will per-
form two short movements (= no limit position pro-
grammed).