Emptying The Dust Collecting Drawer En - Abicor Binzel FES-200 W3 Instrucciones De Servicio

Ocultar thumbs Ver también para FES-200 W3:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FES-200 W3
16
15
14
13
12
11
10
Rubber gasket
1
2
Turbine
Fastening screws
3
Compressed air connection for dedusting
4
Fig. 2
Functional Description
Harmful fumes are produced during the welding process. A permanent filter located in the filter housing
removes the welding fume particles from the sucked air. The cleaned air is led back into the work area via
the exhaust box (12).
If the minimum volume flow is not reached, the manometer (10) indicates a high value and an acoustic
signal sounds. Then the filter must be cleaned with compressed air. During the dedusting procedure, the
exhaust fume deposits are removed from the filter elements and the filter is refreshed.
The separated dust is collected in a dust collecting drawer (8).
NOTICE
• The dust collecting drawer (8) must be emptied before and after each dedusting of the filter.
• After each use, the dust collecting drawer must be checked.
• In case of a filling level of 2/3 or more, the dust collecting drawer must be emptied according to the
The FES-200 W3 is equipped with an automatic Start-Stop system. Use the current clamp to switch on
automatically the fume extraction system by fixing it to the cable assembly of the welding device.
 6 Putting into operation on page EN-14
The rotary switch (11) is used to switch on and off the fume extraction system.
1
2
3
Filter cartridge
5
6
Extraction hose connection
Seal plug
7
Dust collecting drawer
8
regulations.
 5.1 Emptying the dust collecting drawer on page EN-10
5 Functional Description
4
Knurled nut
13 Power cable connection
9
10 Manometer
14 Fuse 250 V, 2.5A delay-action
11 Rotary switch (I-0-Auto)
15 Current clamp connection
12 Exhaust box
16 Counter nut
5
6
7
8
9
EN - 9

Publicidad

Tabla de contenido
loading

Tabla de contenido