below the flow control. This is normal in operation.
Position the unit in the pond. The fountain angle can
be adjusted to be vertical using the ball joint (Fig 2-A).
The tightness of the ball joint can be adjusted (Fig 2-J).
If required, the 2-Tier Fountainhead can be used to
achieve an alternative and higher display pattern than
the 3-Tier.
The fountain height can be adjusted to suit your needs
by rotating the Fountain Flow Adjuster (Fig 3-K).
The Bell Fountain creates a decorative waterbell. The
size of the bell can be adjusted to suit your needs by
rotating the Fountain Flow Adjuster (Fig 3-K).
Waterfall Only Operation
(Fig 4-B for general installation guide)
Position the pump as previously described.
Attach a suitable length (3m maximum) of 25 mm (1")
hose to the waterfall hose tail (Fig 1-G) and secure
with a suitable hose clip and position the outlet end of
the hose in the desired position.
Screw the waterfall hose tail to the fountain outlet of
the EasyClear™ (Fig 1-A) and adjust the flow using the
fountain flow adjuster, (Fig 3-K), to suit your needs.
Note: The maximum recommended waterfall height
above pond level is 0.5m (Fig 4-B).
UVC Operation
The UVC will automatically switch on once the unit
has been connected to the electricity supply if the
bayonet tube is correctly locked in place.
The UVC lamp can be checked for operation by
looking for a bluish glow from ball joint outlet (Fig
1-A). Please note that this may only become visible in
low light conditions.
See Maintenance section for Lamp replacement.
Maintenance
The Hozelock Cyprio EasyClear™ has been designed
to allow fast and easy maintenance. As with all pond
equipment, occasionally it will become necessary to
clean or replace parts.
WARNING: Disconnect this product from the
electricity supply and refer to the section "Safety
& Electrical Connections" before attempting any
maintenance.
Fountain Head (Fig 1-I)
Follow the below procedure if the fountain head is
blocked:
1 - Place a coin or similar in the slot and gently lever
off the fountain head.
2 - Rinse in clean water and reassemble.
Foam
Follow the below procedure if flow appears reduced:
1 - Release the Foam Cover by pushing the two
buttons (Fig 5-M) and lift the cover (Fig 6-N).
2 - Remove the Foam (Fig 7-O). Note:- If the unit is
out of the pond for more then 20 minutes the
biological filter action may stop working. Rinse
thoroughly in pond water (do not use tap water).
3 - The Foam Cover and Base should also be rinsed in
pond water (do not use tap water).
4 - It may also be necessary to clean out the
biomedia and stones (Fig 7-P) if these have
become clogged. If this is necessary, the biomedia
and stones should be rinsed in pond water only.
5 - Reassemble the Filter.
Quartz Tube
Follow the below procedure if your pond remains
green:
1 - Remove the bayonet locking screw (Fig 8-Q), twist
and lift the bayonet tube (Fig 8-R).
2 - Clean the Quartz Tube. Take extra care when
handling the Quartz tube. In hard water areas,
the quartz tube may become covered in limescale,
which will reduce efficiency. Clean the tube with a
soft cloth and a gentle de-scaler (such as vinegar
and water), rinse in water before refitting.
3 - Reassemble the bayonet tube and screw and
restart (Fig 8-S).
Warning! Ensure that the quartz tube is not
damaged before refitting.
Lamp Replacement
Follow the below procedure if the lamp needs
replacing or does not illuminate:
Change the lamp at the start of the new season. Even
though the lamp still glows it may not be giving out
anyuseful UV radiation. How well the EasyClear™
performs is related to the strength of the UV radiation
produced. This will slowly decline from the day your
lamp is switched on. The UVC lamp has an effective
life of 12 months. You need to change the lamp when
there is a significant reduction in water clarity. Make
sure this is due to an expired lamp and not a badly
maintained filter or a dirty/limescaled quartz sleeve.
Both can greatly reduce UV transmission into the
water.
1 - Remove the bayonet locking screw (Fig 8-Q), twist
and lift the bayonet tube (Fig 8-R).
2 - Unscrew the quartz tube locking collar (Fig 9-T-i).
Gently hold the quartz tube (Fig 9-T-ii), lift up and
remove together with its o-rings (Fig 9-T-iii) and
locking collar.
3 - Remove the old lamp by gently pulling it from
its holder (Fig 9-U). Dispose of the old lamp