3.2 LED indicators

FPAC-MAX FINGERPRINT reader is equipped with three LED indicators on its enclosure which
function according to table 3.
Table 3. LED indicators
Name
Symbol
STATUS
OPEN
SYSTEM

3.3 Power supply

AC-MAX FINGERPRINT reader requires 12 Vdc supply voltage. The supply must be connected
to +12Vdc terminal and GND terminal. The GND terminal is also reference potential for RS485
bus. All devices, which are connected to the same RS485 bus should have common ground
(GND). In order to ensure this, all GND terminals of various power supply units in the system
must be connected with each other using separate wire. Alternatively, the common negative
pole (GND) of the entire system can be earthed, but only in single point.

3.4 Wall mounting

Colour
Description
Red/Green
Armed/Disarmed mode of reader
Green
Door unlocked
Orange
Various
microcontroller memory failure, configuration
errors, etc.
FPAC-MAX READER
Fig. 4 FPAC-MAX FINGERPRINT installation
signalling