4.6 Full memory reset

Full memory reset clears the current settings, including the user database, and restores the
factory default settings.
Reset procedure
1. Disconnect the power from the FPAC-MAX FINGERPRINT READER.
2. Connect the CLK terminal to the IN2 terminal. (fingerprint reader's own terminals)
3. Connect the power to the FPAC-MAX Fingerprint READER. The reader will generate a
continuous acoustic signal.
4. Disconnect the CLK and IN2 terminals. (fingerprint reader's own terminals)
Communication parameters after reset:
IP Address - 192.168.0.70
Subnet Mask - 255.255.255.0
Port 13544
Communication is encrypted with a default password (empty)