MAIN UNIT

Ready to in ate indicator
Blood pressure level
classi cation indicator
Irregular heartbeat symbol
Memory indicator
Date/time (alternating)
wrist cu

INSERT OR REPLACE BATTERIES

When LCD shows battery symbol, replace all batteries with
new ones.
1. Slide the battery cover in the direction of the arrow
to open.
2. Insert four alkaline AA batteries in the correct polarity
direction. Inserting them incorrectly may damage the
device and void the warranty. Never use rechargeable
batteries. Use single use batteries.
3. Replace the battery cover.
Disposal
of
empty
collecting party subject to the regulation of each individual
territory.
With the use of four alkaline "AA" batteries, you can measure
approximately 250 times at room temperature of 72°F (22°C)
and inflating to around 170mmHg once a day. But the included
batteries only for test purpose may not last as long as the
specified period.
If the unit will not be used for a long period, please take out all
batteries to avoid liquid leakage damaging the unit.
22
Visiomed - KD-558 - 032016
Low battery
Systolic
Diastolic / pulse
(alternating)
MEM button
START button
LCD display
battery
to
the
authorized.

TIME AND DATE OF SYSTEM SETUP

1. Press the START and MEM button after a
beep the month will blink.
2. Use the MEM button to adjust the month.
3. Press the START button to save your
settings and display the day.
4. Use the MEM button to adjust the day.
5. Follow the steps to adjust the time then the minute.
6. The monitor will turn off automatically after 1 minute of
inactivity.
7. Once you change the batteries, you should readjust the time
and the date.

CONNECTING THE CUFF TO THE MONITOR

Insert the cuff tubing connector into the
socket in the left side of the monitor. Make
certain that the connector is completely
inserted to avoid air leakage during blood
pressure measurements.
Avoid compression or restriction of the connection tubing
during measurement This may cause inflation error, or harmful injury
due to continuous cuff pressure.

A FEW SUGGESTIONS BEFORE MEASUREMENT

1. Avoid eating, smoking, and exercising for at least 30 minutes
before taking a measurement. Also rest for at least 15 minutes
before taking a reading.
2. Stress raises blood pressure. Avoid taking measurements
during stressful times.
3. You would better apply the cuff on your left upper arm.
4. Measurement should be taken in a quiet place and you should
be relaxed in a seated position. Rest your left arm on a table.
5. Remain still and do not talk during the measurement.
6. Wait 5-10 minutes between successive measurements. Waiting
allows the engorged blood vessels to return to normal. You
may require more rest time depending on your individual
physical conditions.
7. Please refer to the cuff circumference range in "SPECIFICATIONS"
to make sure that the appropriate cuff is used.