FILLING SOLUTION TANK

ATTENTION: For Models equipped with the FaSTt
Option. USE CLEAR COOL WATER ONLY. DO NOT
add cleaning agents in solution tank. Conventional
cleaning agents/restorers may cause failure to the
FaSTt solution system.
1. Transport machine to filling station. Raise
squeegee and brush when transporting.
2. Turn main switch to the off position.
3. Open solution fill door at front of machine and fill
solution tank with 64L (17 gal) of clean water,
60°C (140°F) maximum temperature. Or use the
rear fill port to fill solution tank. Twist off plug and
insert hose to fill. The clear tube below the fill port
has 19L (5 gal) increment markers to indicate
amount of water in tank (Figure 13).
FIG. 13
NOTE: If filling with a bucket be certain that bucket is
clean. This will prevent possible solution line clogs.
4. Add cleaning chemical. See proper dilution ratio
instructions on bottle.
FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.
ATTENTION: Use only recommended cleaning
chemicals, DO NOT use substitutes. Consult an
authorized distributor for recommendations.
WARNING: Do Not Use Flammable Liquids Or
Operate Machine In Or Near Flammable Liquids,
Vapors Or Combustible Dusts.
Speed Scrubt 2401/2601 (07–02)
Home
Find... Go To..

MACHINE OPERATION

FOR SAFETY: Do not operate machine unless
operator manual is read and understood.
PRE–OPERATION CHECKS
S
Sweep and dust mop floor to remove particles and
other debris.
S
Check battery meter charge level to ensure
batteries are fully charged (See BATTERY
CHARGING).
S
Check condition of pads or brushes.
S
Check condition of squeegee blades.
S
FaSTt Scrub Mode (option): Make sure that the
solution tank is filled with clear cool water only. All
conventional cleaning agents/restorers must be
drained and rinsed from solution tank. Check
FaSTt PAK agent level, replace carton as needed.

OPERATING MACHINE

NOTE: If your machine is equipped with the FaSTt
Option, refer to page 13 for additional operation
procedures.
1. Release parking brake lever if equipped.
2. Adjust control grips to a comfortable operating
height, squeeze together the two levers below the
console (Figure 14).
FIG. 14