In both cases, set the lever pivot drum in 4 position Set the stirrer in position Fig.1.
Switch off the mixer and pull the plug if you have to touch the mixer with your hands
or any tool for the purpose of cleaning. Do not switch on the mixer during cleaning. Do
not expose the engine housing and the switch to direct water jet. This also applies to
the ventilation apertures to cool the engine.
With the rotating lever rotate the mixer into position 3. Clean obligatorily after each
use. To clean the inside of the mixing drum, use a scraper and a metallic brush, and
rinse with water jet. Remove immediately all concrete or mortar residues on the crown
gears.
The mixer has been designed and manufactured in such a way that it does not need
any particular maintenance. NEVER GREASE THE CROWN GEARS!!!! Observe
the INSTRUCTIONS on the control of the operation of the mixer which are given in
the INSTRUCTIONS on safety and operation, use and storage. Make sure that the
mixing drum is rotating gently. Check that the screws are properly tightened. To extend
the service life of the mixer and a trouble-free operation, they should adhere to the
following notes. After cleaning, the movements in position No.: 4 make (see transport
instructions.) The mixer in the dry and airy room store. If you not are using their mixer
length of time, it is necessary to relax by the drive belts. Loosen the you have relieved
the belt screws and slow lifting of housing the drive device for approx. 2 mm. With
this relaxation of the drive belt, you must take care that you raise the housing of drive
device not too much because the belt could otherwise fall. If it happens but you raise
the housing quite and hire belts properly. Take otherwise there may be damage to
good fit of the belt.
17
CLEANING
Pull the plug each time before cleaning.
leaning forbidden, especially with water, as long as the
cap of the engine housing has not been placed back.
MAINTENANCE
Before cleaning the mains plug out of the socket mixer.