Switch off the mixer by pulling the plug. Never switch on the mixer during any repair
work. If it is necessary to remove or switch off any safety devices, they must be
remounted upon completion of the repair work. Only the manufacturer or authorized
technician may repair electrical parts. Use only original spare parts.
PROBLEM
The engine does
not start up.
The engine starts up
(hums)
but
mixing drum does
not rotate.
1.
01
Engine housing
2.
01
Small crown gear
3.
01
Drum Gear
4.
01
Single phase electric motor
5.
01
Driving axle
6.
02
Engine bearing
7.
01
Plug
8.
01
Electro magnetic emergency
STOP switch
Always pull the plug before any repair work
MALFUNCTIONS
POSSIBLE CAUSE
No power. Defective cables.
The
thermostat
connected. The engine is
overloaded. The ventilation
apertures
are
or
considerably
Foreign part in the conduct
or mechanical deformed of
the conduct.
The crown gear is blocked.
The belt is not tightened
enough. The belt is broken.
The elastic pin on the small
crown
gear
the
The elastic pin on the
pulley is broken. Defective
condenser.
SPARE PARTS
REPAIRS
is
not
obstructed
reduced.
is
broken.
Z=12
Z=132
P1=700/850/1000W;S1=(6-25%)ED;IP00
Ø17
6003 (2RSR)
P224-7
DKLD DZ-6;IP 55
REMEDY
Check the fuse. Check the
cable (electrician). Let the
engine cool down. Check the
are obstructed or considerably
reduced. ventilation apertures
(obstructed or Foreign part
in the conduct or mechanical
deformed).
Switch off the mixer. Pull the
plug. Tighten the pulley. Check
the pin on the small crown
gear. Replace it, if necessary.
Remove the cap of the engine
housing. Check the belt and
the pin of the pulley. Replace
them, if necessary. If the mixing
drum still does not rotate,
call
an
expert
condenser).