Southwire M300P Instrucciones De Uso página 8

Mapeador profesional de cable vdv
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation
Using the Tone Generator to Trace a Data Cable cont.
5. The pins the tone is being sent through will be shown on the bottom of
the display. Repeatedly press the CYCLE button to select the desired pins.
Refer to sequence chart (D) below for explanation of pin selection.
(D)
1
2
3
4
1 2
3 6
4 5
1 2 3 4 5 6 7 8
NOTE:
When tracing a cable run from the tone generator to the end of the
cable, applying the tone on a single pin will allow the tone to be detected at a
greater distance from the cable. When trying to locate a cable in an equipment
room or patch panel, sending the tone through all 8 pins or a single pair will
limit the tone signal from spreading to other nearby cables. The tone will be
loudest when the probe tip is placed directly on the wires the tone is being
sent through at the end of the cable. When sending a tone through a single pair,
verification can be made by shorting the suspected pair. The tone will be very
faint when the pair the tone is being sent through is shorted.
5
6
7
8
Tone will be sent
through selected pin
Tone will be sent
7 8
through selected pair
Tone will be sent
through all 8 pins
13
Operation
Cable Identification on Installed Data Cable
NOTE:
The M300P includes 5 remote ID's for data cables and 5 remote
ID's for coax cables. Expansion Kits are available for a maximum of 16 remotes.
The remote ID's can be used to identify cable runs from the patch panel
to a wall port. Each identifier has a labeled ID number. When the tester is
connected to a cable that has an identifier attached at the other end,
the tester will display the ID number that is marked on the identifier.
Wall Plate
3
RJ45
Remote ID:
5 remotes
(numbered 1- 5)
Remote ID
1. Connect the numbered remote ID's to the port
for each cable that needs to be identified.
2. At the wiring closet or patch panel, connect the unknown cable
to the RJ45 port on the tester.
3. Set the rotary function switch to Data.
4. If the cable being tested is connected to one of the remote ID's,
the display will indicate the number that corresponds to the remote.
NOTE:
The RJ45 remote ID's do not test the wiring on the cable.
Only the detachable remote can identify wiring faults. The remote may not
identify the cable if the cable is miss-wired.
M300P
Patch Panel
Tester
CYCLE
MODE
14

Publicidad

Tabla de contenido
loading

Tabla de contenido