3
Safety
This document contains important information that is presented either as a
warning, caution or note. See the following examples:
WARNING!
Risk of personal injury.
Warnings indicate a potential hazard to the health and safety of personnel,
and how that hazard may be avoided.
CAUTION! Risk of equipment damage.
Cautions indicate a potential hazard to the product but not to personnel, and
how that hazard may be avoided.
NOTE! Notes contain other information that is important for personnel.
4
Technical data
Table 4-1: Dimensions
Item
Maximum pressure
Minimum pressure (for safe operation)
Recommended pressure
Air quality
Working temperature
Wiring gauge
Solenoid voltages
Frequency
Equipment type
5
Description
TAV 100/150 is a valve for automatic opening and closing of a vacuum outlet
linked to a central vacuum system. It comes in six different models. The valves
are normally automatic, they open and close governed by a control device.
The control device can be a solenoid valve for electric control. TAV 100/150 PC
is not fitted with its own control device but an external 5-port valve is available
as an option (see figure 6). All versions are compressed air powered except for
MA which is manually operated.
All valves can be provided with an optional pilot switch to control the
vacuum unit so it stops if no valve is open and then starts again when a valve
opens. This requires a pilot signal cable and a vacuum unit provided with an
automatic start/stop function. Manual valves use a micro switch according
to figure 3 and 7. Pneumatically controlled valves use a pressure-controlled
switch according to figure 5 and 8.
Dimension
1 MPa (10 bar)
0,5 MPa (5 bar)
0,6 - 0,7 MPa (6 - 7 bar)
ISO 8573-1 class 5
0 – 40 ºC
minimum 0,75 mm
2
115 V AC (+10% -15%)
230 V AC (+10% -15%)
24 V DC (+ -10%) or
24 V AC/DC (not ATEX)
50 / 60 Hz for AC
II 3D Ex h IIIC T85ºC Dc
0ºC≤Ta≤40ºC
Nederman 19.HB06 (ATEX-products)