Descargar Imprimir esta página

Gas Pressure Control - Fimar B/50 Uso Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 85
Pilot flame nozzle replacement
1 - Remove the residue tray and
relevant tray cover.
2 - Unscrew the nozzle (E) and re-
place it with the one suited for
the gas used.
3 - Reassemble the residue tray
and relevant tray cover.
GB

GAS PRESSURE CONTROL

Proceed as indicated
1 - Close the gas supply faucet.
2 - Loosen the screws and remove
the front panel.
3 - Loosen the pressure fitting
screw (F).
4 - Connect the pressure gauge to
the pressure fitting (G).
5 - Open the gas supply faucet.
6 - Turn on the burner, rotate the
knob to the maximum power
position.
7 - Make sure the pressure indicat-
ed on the gauge corresponds to
the one on the appliance plate.
- 18 -
LAVA STONE GRILLS
E
IDM-34601900600.tif
F
G
IDM-34601900300.tif
English language

Publicidad

loading

Este manual también es adecuado para:

B/80B/115