Heat Pump
CK15BR / CK20BR / CK25BR / CK30BR
Model
Voltage Range **
Power Supply Cable Size *
Number Of Conductors
Interconnection Cable Size *
Number Of Conductors
IMPORTANT:
* These values are for information only. They should be checked and selected to comply with local and/or
national codes and regulations. They are also subject to the type of installation and size of conductors.
** The appropriate voltage range should be checked with label data on the unit. ETL listed is only applicable
to 60Hz power supply only.
CK15BR / 20BR / 25BR <> SL15BR / 20BR / 25BR
4WV
OF
COMP
Terminal Strip
L
Indoor Unit
N1
N2
Indoor
CK15BR
Outdoor
SL15BR
220 – 240V /1Ph /50Hz + ! or 208 – 230V /1Ph /60Hz + !
2
mm
1.5
3
mm
2
1.5
5
Outdoor Coil Sensor
Interconnection Cable
Power Supply
Cable
1-9
CK20BR
CK25BR
SL20BR
SL25BR
2.5
2.5
3
3
2.5
2.5
5
5
4WV
OF
Terminal Strip
COMP
Outdoor Unit
N
The electrical power must be provided with
!
protection devices (circuit breaker or fuse) with
double pole separation system (phase + neutral)
with minimum contact gap of 3mm.
CK30BR
SL30CR
4.0
3
2.5
6