Chamberlain LiftMaster Professional CB224 Instrucciones Y Instalación página 22

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

FUSES:
F1 = 10A secures the motor
F2 = 1A secures accessories terminals 8 + 9
CONNECTIONS:
1.
24VAC input
2.
24VAC input
3.
motor output
4.
motor output
5.
limit switch COM blue
6.
limit switch UP brown/blue
7.
limit switch DOWN blue/brown
8.
accessories supply 0 Volt
9.
accessories supply 24 Volt
10.
photo cells COM
11.
photo cells DOWN (close)
12.
photo cells UP (open)
13.
switch: COM
14.
switch: UP / DOWN
15.
switch: pedestrians
16.
switch: stop (emergency stop)
17.
antenna signal (not necessary if receiver 80 17 19 6 is used)
18.
antenna ground
BACKUP BATTERY (OPTIONAL):
A backup battery may be connected. It will supply the unit for a while
with power in case of power cut. Depends on battery size and daily
amount of cycles. Model CM475 requires a waterproof housing when
installed outside.
DESCRIPTION OF LED'S
L1
limit switch UP status: ON = limit switch not activated
OFF = limit switch activated (gate positioned at limit
switch)
L2
limit switch DOWN status: ON = limit switch not activated
OFF = limit switch activated (gate positioned at limit
switch)
L3
safety input DOWN (10+11): ON = locks control
OFF = OK
L4
safety input UP (10+12): ON = locks control
OFF = OK
L5
input for switching device (13+14): ON = signal is active
OFF = no signal
L6
input for switching device (13+15): ON = signal is active
OFF = no signal
L7
STOP contact: ON = OK; OFF = locks control
L8
Board Status Indicator
OFF = control in neutral (steady) ; gate positioned on limit
switch DOWN
ON = a signal has been transmitted. LED remains ON until
gate reaches limit switch DOWN again or until pre-
programmed time for closing sequence has lapsed.
TURN-SWITCH FOR PROGRAMS 0-9
Position 1:
Standard
Gate opens after signal and closes with the next one. During opening
sequence the gate first stops and closes and does not close until the
next signal. If photo cell transmittance is interrupted during closing
sequence, the gate reverses to the fully UP position.
Position 2:
Automatic (photo cells necessary)
Gate opens after signal and closes depending on pre-programmed
time (in menu P3). If photo cell transmittance is interrupted during
closing sequence, the gate fully reverses and closes again after pre-
programmed time.
Position 3:
Photo cells close gate
Gate opens after signal and closes as soon as photo cell
transmittance is interrupted. Interrupting photo cell transmittance
during closing sequence results in the gate reversing completely and
then closing again after pre-programmed time (in menu P3).
Position 4:
counting mode
Gate opens after signal and counts the number of signals that were
given. There have to be at least the same number of interruptions at
the closing photo cells (CLOS) before the gate actually closes (this
program is not possible if two photo cells have been installed in
closing direction).
Position 5-0:
no function
Plug-in socket – JP3
Enables further functions either through direct connection or via relay
to another control, e.g. alarm system / telephone / status indicator
gate / computer / counter, etc.
Pin 5 = control / gate status: ON = when control active
Pin 4 = 0 Volt
Pin 3 = + 12 Volt for accessories max. 100mA!
Pin 2 = AUX ON (switched) = when gate closing
Pin 1 = AUX ON (switched) = when gate opening
10A F US E
+24V
0V
1A F US E
C OM
L1
OP E N
L2
C LS
0V
+24V
C OM
L3
C LS P
L4
OP NP
C OM
L5
P.B .
L6
P E D
S TOP
L7
ANT
L8
G ND
J P 3
J P 6
1 2 3 4 5
1 2 3
OF F
OF F
ON
ON
R eceiver

Publicidad

Tabla de contenido
loading

Tabla de contenido