Chamberlain LiftMaster Professional CB224 Instrucciones Y Instalación página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

PROGRAMMING OF CONTROL
The control is programmed by use of the display. The keys and switches on the right side next to the display are required.
Switch 1:
ON = necessary for programming the control
Switch 2:
ON = display illumination on
Key SET:
saves current setting
Key UP & DOWN: changes setting
Key NEXT:
to change to different menu / program
DISPLAY INDICATION:
P... =
display of currently accessed menu / program
Def. =
"DEFAULT" factory setting. Ex factory setting
Now =
"NOW" current setting
Yes
"YES"
No
"NO"
D
s i
p
a l
y
P1= Motor Type
P1
Def: 0 Now: 0
P2 = M1 Travel Time
P2
Def: 5 Now: 5.0s
P3 = Auto Cls Delay Def: 1
P3
Now: 1.0s
P4 = M1 Force Adj
P4
Def: 50% Now: 50%
P5 = Slow Down
P5
Def: 3 Now: 3.0s
P6 = M1 Soft Start
P6
Def: 0 Now: 0.5s
P7 = Back Up Timer
P7
Def: 0 Now: 0.0s
P8 = Open PE Type
P8
Def: RLY Now: RLY
P9 = Close PE Type
P9
Def: RLY Now: RLY
P10 = PE Reverse
P10
Def: Yes Now: Yes
P11 = Opn PE ReOpen
P11
Def: No Now: No
P12 = PED Travel
P12
Def: 5 Now: 5.0s
P13 = PED Auto Close
P13
Def: No Now: No
P14 = Pwr Fail Close
P14
Def: No Now: No
P15 = Motor Speed
P15
Def: 10 Now: 10
P16 = ExtraOpnTime
P16
Def: 2 Now: 2.0s
P17 = ExtraClsTime
P17
Def: 2 Now: 2.0s
P18 = Battery Type
P18
Def: 24 Now: 24
P19 = BatteryLowOpn
P19
Def: No Now: No
P20 = RPM Sense
P20
Def: No Now: No
P21 = Total Cyles
P21
#Cycles = 0000000
P22 = Resettable Cycl
P22
#Cycles = 000000
P23 = Reset Cycles
P23
Def: No Now: No
P24 = Reset Default
P24
Def: No Now: No
P25 = Software Rev
P25
Revision .....
D
e
s
r c
p i
t
o i
n
Setting of applied motor: 0 = no motor
motor type
1 = Chamberlain/ LiftMaster; for others: see description
r t
a
v
l e
d
u
r
t a
o i
n
S
t e
r t
a
v
l e
d
u
r
t a
Duration in seconds of door in open position
automatic closing
ATTENTION: only in connection with photo cell(s)
force setting
Motor force
slow travel
S
o l
w
r t
a
v
l e
n i
end
slow travel
S
o l
w
r t
a
v
l e
n i
start
Only in conjunction with program 3: closes door automatically
automatic closing
even after power cut. Time in seconds. Attention: only with connected
special
photo cell(s)
Preselection of photo cell type: RLY – relay photo cell
photocell open-
PLS – pulse (Chamberlain photo cell 770E and 771E)
direction
Preselection of photo cell type: RLY – relay photo cell
photocell close-
PLS – pulse (Chamberlain photo cell 770E and 771E)
direction
photocell closed-
"YES"= gate reverses to open
reaction
"NO"= gate stops
photocell open-
During interruptiongate stops. After clearance "NO" = reverses (closes);
reaction
"YES" = opens further
Pedestrian travel
Travel duration of motor during pedestrian function (in seconds)
duration
Pedestrian
Duration in seconds of gate in open position. P3 must be active.
automatic closing
Attention: only in connection with photocells
power cut
Closes gate automatically even after power failure. Time in seconds.
behaviour
Attention: only with connected photocells
Speed of gate. Note: by reducing, the max. pulling force cannot be
speed
reached
travel duration open
Additional travel duration of motor to compensate for wind or bad
additional
conditions.
travel duration
Additional travel duration of motor to compensate for wind or bad
close-additional
conditions.
battery type
2x 12V, no setting possible
battery
"NO"= gate will not open if battery is empty
state of charge
"YES"=gate will open, but not close
RPM
"YES" = RPM sensor is connected (necessary in the EU) "NO" = if
sensor
nonexistant and if battery is used
cycle counter
counts all full (completed) cycles
complete
cycle counter
counts complete cyles since last reset
resettable
cycle counter reset Reset P22 cycle counter
factory setting
re-establishes factory settings (not P22)
RESET
software
indicates installed software version
OFF = locks
OFF = out
o i
n
f o
m
o
t
o
r
s (
e
c
o
n
d
) s
s
e
c
o
n
d
s
b
e
o f
r
e
d
o
o
r
D
O
W
N
s
e
c
o
n
d
s
f a
e t
r
s
a t
t r
NEXT
UP
DOWN
SET
1
2
My settings
Range
0 - 3
0
-
9
9
0 - 99
30 - 100%
0
-
1
0
0
-
1
0
0 - 65
RLY - PLS
RLY - PLS
No - Yes
No - Yes
0 - 99
No - Yes
No - Yes
1 - 10
0 - 10
0 - 10
24V
No - Yes
No - Yes

Publicidad

Tabla de contenido
loading

Tabla de contenido