POWER REQUIREMENTS

DEDICATED CIRCUIT AND ELECTRICAL INFO
A "Dedicated Circuit" means that each outlet you plug into should not have
anything else running on that same circuit. The easiest way to verify this is
to locate the main circuit breaker box, and turn off the breaker(s) one at a
time. Once a breaker has been turned off, the only thing that should not have
power to it are the units in question. No lamps, vending machines, fans, sound
systems, or any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit must have an individual
neutral/ground connection coming from it, and terminating at an approved earth
ground. You cannot "jumper" a single neutral/ground from one circuit to the next.
ELECTRICAL REQUIREMENTS
For your safety and to ensure good treadmill performance, the ground
on this circuit must be non-looped (isolated). Please refer to NEC
article 210-21 and 210-23. Your treadmill is provided with a power cord
with a plug listed below and requires the listed outlet. Any alterations
of this power cord could void all warranties of this product.
For units with an integrated TV (like the 7xe and 7xi), the TV power
requirements are included in the unit. An RG6 coaxial cable with 'F
Type' compression fittings on each end will need to be connected to
the cardio unit and the video source. For units with an add-on digital
TV (5x only), the machine in which the add-on digital TV is connected
to powers the add-on digital TV. Additional power requirements
are not needed for the add-on digital TV. For units with an add-
on PCTV (5x only), the TV power requirements are separate.
110 V UNITS
All Matrix 5x, 7xe and 7xi 110 V treadmills require the use of a 100-125 V,
60 Hz and a 20 A "Dedicated Circuit", with a non-looped (isolated) neutral/
ground for power. This outlet should be a NEMA 5-20R and have the same
configuration as the plug. No adapter should be used with this product.
220 V UNITS
All Matrix 5x, 7xe and 7xi 220 V treadmills require the use of a 216-250 V,
50 Hz and a 20 A "Dedicated Circuit", with a non-looped (isolated) neutral/
ground for power. This outlet should be a NEMA 6-20R and have the same
configuration as the plug. No adapter should be used with this product.
4
GROUNDING INSTRUCTIONS
The equipment must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current to reduce the
risk of electric shock. The unit is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances. If the user does not follow these
grounding instructions, the user could void the Matrix limited warranty.
ADDITIONAL ELECTRICAL INFO
In addition to the dedicated circuit requirement, the proper gauge wire
must be used from the circuit breaker box, to each outlet that will have
the maximum number of units running off of it. If the distance from the
circuit breaker box to each outlet, is 100 ft (30.5 m) or less, then 12 gauge
wire should be used. For distances greater than 100 ft (30.5 m) from the
circuit breaker box to the outlet, a 10 gauge wire should be used.
110 NEMA 5-15P
ENERGY SAVING / LOW-POWER MODE
PLUG (N.A.)
All units are configured with the ability to enter into an energy saving / low-
power mode when the unit has not been in use for a specified period of
time. Additional time may be required to fully reactivate this unit once it has
entered the low-power mode. This energy saving feature may be enabled
or disabled from within the 'Manager Mode' or 'Engineering Mode.'
220 NEMA 6-20P
ADD-ON DIGITAL TV (T1X AND T3X)
PLUG (N.A.)
A 15 A or 20 A "Dedicated Circuit" with a non-looped (isolated) neutral/ground
is required. Each add-on TV requires at least 1.2 A of current (at 110 V or 220
V). No more than 12 add-on TVs should be used for each 15 A circuit and no
more than 16 add-on TVs should be used for each 20 A circuit. The power outlet
should have the same configuration as the plug. No adapter should be used
with this product. An RG6 coaxial cable with 'F Type' compression fittings will
need to be connected between the video source and each add-on TV unit.
EURO PLUG
(EUROPE)
North American and
European power
cord plugs shown.
Depending on your
country, the plug
type may vary.