41017
In standalone mode, it is possible to configure input CA and
configure the activation time of relay F1.
In slave-2wire mode, input CA is enabled and relay F1 is
configured directly on the AV module. Alternatively, instead of
controlling the output F1 of the device, recognition of a reg-
istered card may be used to control any other output (relay/
lock) of the audio or audio/video module or other auxiliary
modules of the external unit. You can also configure the out-
put F1 as a common or exclusive lock for the external unit.
In the event of an error, the red LED will flash continuously.
Check that: the device is connected to a compatible audio or
audio/video module; the wiring has been connected correct-
ly; the firmware versions of the modules are updated.

3.2 Manual registration

The following manual registration procedure allows you
to add new user cards to the device without having to use
SaveProg:
• Hold a previously registered installer card up to the
reader;
• Within 5 seconds, hold the new card to be registered as
a user up to the reader; the blue LED on the device will
flash rapidly during the registration period;
• Hold the card in position until registration is confirmed;
the green LED will illuminate for 1 second (no com-
mand is activated);
• The procedure then restarts from step 2: the blue LED
starts flashing rapidly, indicating that another user card
can be registered within the next 5 seconds.
If no card is read during the 5 second registration period, or
if there is a fault, the white LED will illuminate and the proce-
dure will be cancelled. Cards registered in this way are giv-
en the name manual-n, where n is the incremental number
assigned to each new card registered. Cards can only be
deleted using SaveProg.
4. Eipvdes and slave-eipvdes modes
Refer to the documentation for Elvox IP and Video Door IP
Manager. These modes do not support the use of installer
cards.
5. Operation
When the device is in standby state, the white LED is illumi-
nated. When a user card is read, the green LED illuminates
for 3 seconds and the programmed command is executed
(activation of output F1 or other command according to the
configuration). If the card presented is not registered, the red
LED will flash for 3 seconds.
6. Updating
The device can be updated using SaveProg/FWUpdate. Dis-
connect the device from the auxiliary power supply and/or
PoE, connect it to the PC by USB cable and start the update
procedure. During the update procedure, the red LED stays
on. If updating does not start within 30 seconds of connecting
the PC by USB cable, the device will return to operating mode
and it will no longer be possible to update it. Disconnect and
then reconnect the USB cable to repeat the operation.
When it is part of an Elvox IP video door entry system
(eipvdes or slave-eipvdes), the device is updated by via
Video Door IP Manager by the network.
NOTE: the device is able to operate in eipvdes and slave-
eipvdes modes and can be managed and updated using
Video Door IP Manager if it is equipped with firmware ver-
sion 1.8.5.3 or later. If not, it can be updated using SaveProg/
FWUpdate.