Installation Of Batteries; External Power Supply - Pulsar QUANTUM HD 38 Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
6

INSTALLATION OF BATTERIES

Turn the lever of the battery compartment (12) 90 degrees in "Open"
position and, pulling by the lug of the cover, remove the battery
container.
Install four AA batteries (or rechargeable batteries) observing polarity
shown on the battery container.
Insert the battery container into the battery compartment and turn the
lever 90 degrees clockwise. '
Note: to ensure long and reliable operation it is recommended that you use quality
rechargeable batteries with a capacity of at least 2500 mAh. Please do not use batteries of
different types or batteries with various charge levels.
7

EXTERNAL POWER SUPPLY

The scope can be powered with an external DC power supply (2.1mm
pin) with stabilised voltage ranging from 8.4V to 15V (max. consumption
power 3W) or a 12V vehicle socket.
External power supply (AC/DC) is to be connected to "Power" (10)
jack located on the bottom side of the device.
Please note that the central pin of the power supply that you connect to
the "power" jack of the riflescope, must have marking "+". The power
supply may have marking -
Connection of an external power supply (icon
automatically cuts off power supply from batteries.
External power supply DOES NOT charge the rechargeable batteries in the unit.
Attention! We suggest that you use battery packs EPS3 or EPS5 ensuring from 9 to 20
hours of operation.
8
OPERATION
Switching on and calibration
Press "ON" (1) to switch on the unit. Green LED indicator (14) will light
up. In case of low battery the LED will turn red and battery icon will start
flashing .
Do the calibration of image. Calibration levels background temperature
of the microbolometer and eliminates image flaws. To calibrate, press
"CAL" (2) without opening the lens cap. Image will freeze for 1-2
seconds, message "CALIBRATION" will show up on the data panel,
when the message disappears, calibration is completed.
6
shows up on the data panel)
Focusing and image adjustment
Open the lens cap (4) and fix it in the hole (15) in the bottom part of the
unit. Adjust the sharpness of the display icons by turning the eyepiece
ring (13).
To adjust display brightness, rotate the encoder (5). Brightness level
(from 1 to 20) will show up next to the brightness icon
panel.
To adjust display contrast press the encoder (5) (icon
and rotate it. Contrast level (from 1 to 20) will show up next to the
contrast icon on the data panel.
Point the unit at a warm object located at a certain distance, 100
meters, for example.
Adjust the focus by turning the ring for lens internal focusing (6).
After this adjustment no further dioptre adjustment should be required,
regardless of distance or other factors. Adjust image quality only with
the ring for lens internal focusing.
Other functions
Press "ZOOM/INVERT"(3) to activate digital zoom (only in models
).
384x288
Keep "ZOOM/INVERT"(3) pressed for two seconds (in 160x120
models no waiting is needed) to activate colour inversion (functions
"Hot white" and "Hot black").
When function "White hot " is used, warm objects are represented in
shades of bright colour;
"Black hot " represents objects in shades of dark colour.
Press "ON" (1) to switch off the unit.
9
MENU
The menu includes two functions:
- Clock;
- Video output signal selection.
Function "Clock":
To enter the menu, keep the encoder (5) pressed until icon
up. Press the encoder shortly to confirm the function selected.
Rotate the encoder (5) to select time format ("24" or "AM/PM")
(editable parameter is flashing).
To pass to minute/hour setup press the encoder (5). Rotate the
encoder to adjust minute/hour parameter.
To exit the menu, keep the encoder (5) pressed for two seconds.
on the data
will show up)
shows
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Quantum ld 38Quantum hs 19Quantum ls 19

Tabla de contenido