Identification Plate - Ashland PUMP AGPR Serie Operación, Rendimiento, Especificaciones Y Manual De Piezas

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note: Rotation should be clockwise when observed from
the top of the pump. This can be checked by noting
which direction the pump torque is upon initial starting.
A properly rotating pump will torque counterclockwise
upon start.
Note: Each cable has a green ground wire and must be
properly grounded per the National Electric Code and
local codes.
Electrical Motor Controls: All electrical
controls and motor starting equipment
should be as specified in these instructions.
Grinder Pumps
Model: AGPR Series
Receiving and Installation
Pre-operation
CHECK VOLTAGE AND PHASE
Before operating pump, check to make sure that voltage
and phase information stamped on the pump's identifica-
tion plate matches the available power.
CHECK PUMP ROTATION
Before putting pump into service for the first time, the
motor rotation must be checked. Improper motor rota-
tion can result in poor pump performance and
can damage the motor and/or pump.

IDENTIFICATION PLATE

Note the numbers on the pumps identification plate and
record at the end of this manual for future reference.
Thermal Protection
On single phase models,the normally closed (N/C) over
temperature sensor is embedded in the motor windings
and will detect excessive heat in the event an overload
condition occurs. The thermal sensor will trip when the
windings become too hot and will automatically reset
when the pump motor cools to a safe temperature.
In the event of an over temperature, the source of this
condition should be determined and repaired immediately.
Thermal protection shall not be used as a motor overload
device.
6