UCC T3 installation guide
www.renishaw.com
Connectors and signals for the UCC T3
controller
Rear panel
The connectors on the rear panel of the UCC T3 controller enclosure are shown below:
DC power in
3W3 socket. The UCC T3 controller is powered from an external DC power source through this connector, which can be purchased in a
connector kit from Renishaw.
Pin
Function
A1
0 V
A2
24 V to 80 V
A3
0 V
DC power specification
• Voltage 24 V to 80 V
• Current input to 10 A
The UCC T3 controller requires 30 W of power to support the controller functions integrated into the unit. This must be factored into the
power supply used.
CAUTION: For ambient temperatures between 40 °C and 50 °C, the maximum input power should be 400 W.
CAUTION: UCC T3 is not recommended for use in ambient temperatures above 50 °C.
Issued 04 2019
22