Filter Replacement - Renishaw UCC T3 Guia De Instalacion

Tabla de contenido

Publicidad

UCC T3 installation guide
www.renishaw.com
Maintenance

Filter replacement

The UCC T3 controller has a positive air flow within its enclosure for cooling purposes; this system has a replaceable filter to protect it from
the ingress of dust. The machine operator should check the condition of this filter on a regular basis. It is recommended that this filter is
removed and checked then replaced as necessary during the machine installer or retrofitter's regular maintenance routine.
Exchanging / removing the air filter
The following procedure is recommended when exchanging / removing the air filter:
1. Remove power from the controller.
2. Remove the 19 inch rack mounting brackets (if fitted) by removing the two fixing screws.
3. Individually pull the heads of both the filter-retaining clips away from the unit about 5 mm for them to disengage. This should permit the
external filter cover to be pulled away.
4. Remove the filter material from the filter recess.
5. Replace the filter, reversing the steps given above (the part number of the replacement filter is A-5518-0011).
Issued 04 2019
41

Publicidad

Tabla de contenido
loading

Tabla de contenido