(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
Do not load any staples in the Stapler.
Set the switching device to the upward position
(SINGLE SEQUENTIAL ACTUATION MECHANISM).
(Set the switching device to the upward position
completely as shown in the diagram. Otherwise, it will
not operate properly.)
□ THE STAPLER MUST NOT LEAK AIR.
(3) With fi nger off the trigger, depress the push lever
against the workpiece.
□ THE STAPLER MUST NOT OPERATE.
Depress push lever
(4) Separate the push lever from the workpiece.
Next, point the stapler downward, pull the trigger and
then wait in that position for 5 seconds or longer.
□ THE STAPLER MUST NOT OPERATE.
Upward position
Switching device
Do not pull
trigger
).
2
(5) 1 Without touching the trigger, depress the push
lever against the workpiece.
Pull the trigger.
□ THE STAPLER MUST OPERATE.
2 Remove the fi nger from the trigger.
□ Stapler operation will end (the driver blade will
return to the top).
(6) Set the switching device to the downward position
(CONTACT ACTUATION MECHANISM).
(Set the switching device to the downward position
completely as shown in the diagram. Otherwise, it will
not operate properly.)
With the Stapler off the workpiece, pull the trigger.
Depress the push lever against the workpiece.
□ THE STAPLER MUST OPERATE.
(7) If no abnormal operation is observed, you may load
staples in the Stapler.
Drive staples into the workpiece that is the same type
to be used in the actual application.
□ THE STAPLER MUST OPERATE PROPERLY.
English
Pull trigger
Switching device
Downward position
13