Cleaning The Housing; Cleaning The Inside Of The Device; Replacing The Toothed Belt; Disposal - Proxxon FET Manual De Instrucciones

Ocultar thumbs Ver también para FET:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46

13.1. Cleaning the housing

For a long service life, the device should be cleaned after
every use with a soft cloth, hand brush or a soft brush. Even a
vacuum cleaner can be recommended.
Cleaning the outside of the houses can be done with a soft,
possibly moist cloth. A soft detergent or other suitable cleaning
agent may be used. Avoid using solvents or alcohol-based
cleaning agents (e.g. benzine, rubbing alcohol, etc.) as these
will affect the plastic housing shells.
If, despite using the dust suction during operation, it is neces-
sary to clean the inside of the device, please simply swing up
the upper housing part and vacuum the inside of the device
with a vacuum cleaner.

13.2. Cleaning the inside of the device

Caution!
Never use compressed air for blowing out! The fine wood dust
could become lodged inside the motor or on electrical compo-
nents and impair the reliability and the safety of the machine!
1. Make sure the mains plug is disconnected!
2. Swing open the upper housing part (see also section 6.2
„Unpacking")
3. Vacuum the inside of the device with a vacuum cleaner
4. Push down the upper housing part and lock.

13.3. Replacing the toothed belt

A toothed belt transmits the power from the motor to the saw
blade shaft. The belt has a very long service life, but when the
machine is used extensively, it could be necessary to replace
it after a longer operating period. The procedure is described
here. In case you are unsure, please send the saw to our
Central Service.
1. Make sure the mains plug is disconnected!
2. Set the saw blade to an approx. 40° tilt as explained in
section „Adjusting the saw blade tilt".
3. Swing up the upper housing part as explained in section 6.2
4. Block the shaft with the small Allen key as described in the
Chapter 12.
5. Unscrew the Phillips screw 1 (fig. 17). Remove thrust washer 2.
6. Pull off the old toothed belt 3 and fit the new toothed belt.
Turn the drive at the toothed belt pulleies slightly back and
forth until the new toothed belt sits correctly.
7. Replace the thrust washer 2 and tighten with the Phillips
screw 1.
8. Close the upper housing part and correct the saw blade tilt
as desired.
9. Make sure to remove the Allen key for blocking the shaft
before commissioning.

14. Disposal

Please do not dispose of the device in the household waste!
The device contains valuable substances that can be recy-
cled. For any further questions, please contact your municipal
disposal company or other appropriate municipal institutions.

15. EC Declaration of Conformity

Name and address:
PROXXON S.A.
6-10, Härebierg
L-6868 Wecker
Product designation: Fine cut circular saw FET
Article No.:
27070
In sole responsibility, we declare that this product conforms
to the following directives and normative documents:
EU EMC Directive 2014/30/EU
DIN EN 55014-1 / 05.2012
DIN EN 55014-2 / 01.2016
DIN EN 61000-3-2 / 03.2015
DIN EN 61000-3-3 / 03.2014
EU Machinery Directive
2006/42/EC
DIN EN 62841-1/07.2016
DIN EN 62841-3-1/05.2015
DIN EN ISO 14121-1 / 09.2010
CE-Type certification according to Macine Guidline
2006/42/EC Art. 12.3 (b) was made by VDE Test- and
Certification body (NB 0366), Merianstraße 28, 63069
Offenbach, Germany
Certification number: 40045123
Date: 05.12.2016
Dipl.-Ing. Jörg Wagner
PROXXON S.A.
Machine Safety Department
The CE document authorized agent is identical with the
signatory.
25

Publicidad

Tabla de contenido
loading

Tabla de contenido