Replacing The Filter; Replacing The Centre Brush; Replacing The Side Brush: - IPC Gansow 1010 E Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 58

7.3 - REPLACING THE FILTER

Every 200 hours of work, the filter must be replaced.
To do so:
1 - Lift the bonnet where the seat is located.
2 - Slacken the wing nut on the filter box cover.
3 - Remove the cover.
4- Loosen the 4 locking rings (10) (Panel filter).
5 - Loosen the 4 knobs (11) (Panel filter).
6 - Remove the filter from the filter holder (Panel filter).
After replacing the filter, carry out the above operations
in reverse order.
7- Unscrew the four screws (Pocket filter).
8 - Disconnect the connector on the filter shaker (Pocket
filter).
9 - Remove the filter from its housing (Pocket filter).
10 - Thoroughly clean the filter with a vacuum cleaner or
replace it (Pocket filter).
After replacing the filter, carry out the above operations
in reverse order.
When fastening the filter,make sure that
filter and gaskets are tightproof.
WARNING:To get rid of the filter, follow
strictly the directing laws.
ENGLISH (Translation of original instructions)
fig. 3 OFF.Push the centre brush control lever 6, fig. 2 to OFF.
1 -Loosen the screws fixing the bottom left casing.
2 -Loosen the screw fixing the brush locking arm.
3 -Remove the spring from the brush shaft.
4 -Remove the 4 screws closing the brush compartment.
5 -Remove the flange and the centre brush.
Insert the new brush and make sure that its rows of brushes direct
the wastes towards its centre.
Once the brush has been inserted, carry out the operations in
reverse order to reassemble the machine.
The main brush is an essential part of the machine.Correct regulation
will help you achieve better results in less time.
The machine is delivered regulated; however should you require
further regulations:
Unscrew the bottom right casing;push the lever (6, fig. 2) to its ON
position.
Loosen the nut 10 and the register-blocking counter nut. Verify
that the wire isn't in tension and that there is gap enough for the
pad to be adjusted. If not, adjust the register 7 until you don't have
the gap needed.Adjust the pad by means of the counter nut until
when between the pad and the padblocker there is a gap 4 / 5 mm
Panel filter
roughly.
Re-block the blocking counter-nuts and the sheathing blocking
dowel.
Pocket filter
Push the side brush control lever 5 (5A) Fig.2 to OFF.Loosen the
three screws that secure the side brush to the drive flange.Remove
the brush and replace it with a new one.Tighten the three side brush
fixing screws.The machine is now ready to be turned on.
Fig.4
The side brush directs the material towards the centre ofthe machine
so that it can be drawn into the bin.
It should be high enough to brush lightly against the floor.
Should you decide to increase or decrease the pressure of the brush
on the floor:move the brush to its work position ON.
-Loosen the two adjustment screws under the brush lifting knob.
-Manually adjust the brush.
-Tighten the adjustment screws.
-Move the side brush back to rest position OFF.
7.4

Replacing the centre brush

Before carrying out any work on the machine,
make sure that it is off and that all its functions are
disabled. This is done by turning the key switch 3,
Adjusting the centre brush
7.5

Replacing the side brush:

- Adjusting the side brush:
Pag. 8