3.1 Applications
Grundfos Multilift MD and MLD lifting stations are designed for
the collection and pumping of domestic wastewater with no free
flow to sewer level. Grundfos Multilift MD and MLD lifting stations
are designed for the collection and pumping of the following
liquids:
•
domestic wastewater, including grey wastewater without
faeces, black wastewater with faeces (discharge from water
closets)
•
sludge-containing water.
The lifting stations are capable of pumping liquids containing
fibres, textiles, faeces, etc., below sewer level from multi-family
houses, offices, schools, hotels, restaurants, public areas and
other commercial buildings and similar industrial applications.
Do not pump rainwater with the Multilift MD and MLD lifting
stations for these two reasons:
•
The motors of the lifting stations are not designed for
continuous operation which may be necessary in case of
heavy rainfall.
•
Rainwater must not be discharged into a lifting station inside a
building according to EN 12056-4.
If in doubt, please contact Grundfos for advice.
Do not discharge the following substances/types of wastewater
via a lifting station:
•
solid matter, tar, high content of sand, cement, ash, cardboard,
debris, garbage etc.
•
wastewater from sanitary installations situated above the flood
level (this must be drained away via a free-flow drainage
system according to EN 12056-1).
•
wastewater containing hazardous substances such as greasy
wastewater from large-scale catering establishments.
For drainage of greasy wastewater, use a grease separator
according to EN 1825-2 between a canteen or commercial
kitchen and the Multilift MD or MLD.
4. Transportation and storage
Warning
The motor lifting eye is only intended for lifting the
pump. Never lift or lower the lifting station by means
of the lifting eye.
Lift the lifting station by the collecting tank.
Note
For long periods of storage, the LC 221 controller must be
protected against moisture and heat.
After a long period of storage, the pumps must be inspected
before they are started up again. Make sure that the impellers
can rotate freely.
5. Product description
The MD and MLD Multilift lifting stations are described in the
following sections:
•
section
5.1 Lifting station
describing the lifting station with
collecting tank, pumps, non-return valve and level sensor
•
section
5.2 LC 221 controller
as the functions and operation of the controller.
In section
7. Installation of lifting station
sections, the above components are described as one unit.
describing the controller as well
and the following
5.1 Lifting station
The Grundfos Multilift MD and MLD lifting stations are supplied
complete with two single- or three-phase submersible pumps
connected to the LC 221 controller incorporating a level sensor.
Type key, lifting station
Example
Multilift lifting station
L = large tank
D = 2 pumps
Output power, P
/ 100 (W)
2
1 = single-phase motor
3 = three-phase motor
2 = 2-pole motor
4 = 4-pole motor
Nameplate, lifting station
1
DK - 8850 Bjerringbro, Denmark
2
Typ
Prod.-Nr.
3
P. c.
4
f
Hz
5
Phases
6
U
V
7
A
I
1/1
8
P
kW
1
19
0197
98127055
20
9
Fig. 3
Nameplate, lifting station
Pos.
Description
1
Type designation
2
Product number
3
Production code (year/week)
4
Frequency [Hz]
5
Number of phases + voltage [V]
6
Voltage [V]
7
Full-load current [A]
8
Motor input power P
[kW]
1
9
EAC and CE mark
10
Duty type
11
Serial number
3
12
Maximum flow rate [m
13
Minimum head [m]
14
Maximum head [m]
15
Maximum liquid temperature [°C]
16
Maximum ambient temperature [°C]
17
Weight [kg]
18
European norm identification code
19
Notified Body
20
Reference number for the Declaration of Performance
M
L
D
.22
.3
.4
10
11
Serial no.
12
3
m /h
Q
max
13
m
H
min
14
m
H
max
15
T
Med
C
max
16
Amb
T
C
max
17
G
kg
Made in Germany
18
/h]
7