Technical Data; Product Properties; Maximum Volumetric Flow Rate And Maximum Vacuum - Hilti VC 20M-X Manual Del Usuario

Ocultar thumbs Ver también para VC 20M-X:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
Material
Accessories
number
2278640
DRY VC 20⁄40⁄150 universal filter
2261452
HEPA VC 20⁄40⁄150 filter
203867
36x4,65M AS suction hose
▶ Class M for picking up dust types with an exposure limit value of ≥ 0.1 mg/m3.
▶ Always use a dust bag when working with the M-class vacuum cleaner.
4

Technical data

4.1

Product properties

If the appliance is powered by a generator or transformer, the generator or transformer's power output
must be at least twice the rated input power shown on the rating plate of the appliance. The operating
voltage of the transformer or generator must always be within +5 % and -15 % of the rated voltage of
the product.
Dimensions (L x W x H)
Weight
Maximum additional load
Container capacity
Effective dust capacity
Effective water capacity
Air temperature
Automatic filter cleaning
AC frequency
Protection class
Protection class
Dimensions (L x W x H)
Weight
Maximum additional load
Container capacity
Effective dust capacity
Effective water capacity
Air temperature
Automatic filter cleaning
AC frequency
Protection class
Protection class
4.2

Maximum volumetric flow rate and maximum vacuum

Maximum volumetric flow rate (air)
Maximum partial vacuum
Maximum volumetric flow rate (air)
Maximum partial vacuum
*2268215*
Type of use
Dry
Wet and dry
Wet and dry
VC 20M-X
530 mm x 290 mm x 415 mm
11 kg
25 kg
15 ℓ
15 kg
9 ℓ
−10 ℃ ... 40 ℃
sensor-controlled
50 Hz ... 60 Hz
I
IP X4
VC 20L-X
530 mm x 290 mm x 415 mm
11 kg
25 kg
15 ℓ
15 kg
9 ℓ
−10 ℃ ... 40 ℃
sensor-controlled
50 Hz ... 60 Hz
I
IP X4
1200 W
1200 W
1200 W
1200 W
2268215
VC 40M-X
560 mm x 365 mm x 590 mm
14.4 kg
25 kg
30 ℓ
34 kg
22.8 ℓ
−10 ℃ ... 40 ℃
sensor-controlled
50 Hz ... 60 Hz
I
IP X4
VC 40L-X
560 mm x 365 mm x 590 mm
14.4 kg
25 kg
30 ℓ
34 kg
22.8 ℓ
−10 ℃ ... 40 ℃
sensor-controlled
50 Hz ... 60 Hz
I
IP X4
VC 20M-X
VC 20L-X
183 m³/h
183 m³/h
245 kPa
245 kPa
VC 40M-X
VC 40L-X
183 m³/h
183 m³/h
245 kPa
245 kPa
English
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vc 20l-xVc 40m-xVc 40l-x351495/0056

Tabla de contenido