Descargar Imprimir esta página

Technical Description; Description; Data Plate; Standard Equipment - CEMONT BLUMIG 243C Instrucciones De Seguridad, Empleo Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
1.0

TECHNICAL DESCRIPTION

1.1

DESCRIPTION

This equipment is a modern and professional power source for
MIG/MAG welding. It is equipped with a patented 4 roll-wire feed
that ensures a smooth wire feed. It has a reinforced cabinet and
Euro connection for torch.
1.2

DATA PLATE

200A
PRIMARY
Three phase supply
Frequency
Effective consuption
Maximum consuption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
250A
PRIMARY
Three phase supply
Frequency
Effective consuption
Maximum consuption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
TECHNICAL DESCRIPTION
230 V
400 V
50 Hz
10,5 A
6 A
19 A
11 A
18 ÷ 35V
35 A ÷ 200A
200 A
140 A
110 A
IP 23
H
Kg. 71
mm 500 x 870 x 950
EN 60974.1 / EN 60974.10
230 V
400 V
50 Hz
15 A
8,5 A
27 A
15,6 A
18 ÷ 40 V
35 A ÷ 250 A
250 A
170 A
140 A
IP 23
H
Kg. 80
mm 500 x 870 x 950
EN 60974.1 / EN 60974.10
300A
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
250A ALU
Three phase supply
Frequency
Effective consuption
Maximum consuption
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
1.3

STANDARD EQUIPMENT

- Earth cable
- Pair of feed rollers for wire diameter 1 mm
1.4

DUTY CYCLE AND OVERHEATING

The duty cycle is the percentage of a 10 minute period for which
the welder can continue to weld without overheating. If the ma-
chine overheats, the welding current is shut off and the relative in-
dicator lamp illuminates. In this case, leave the machine to cool for
approx. 15 minutes and, before restarting, lower the welding cur-
rent value and relative voltage or reduce the work time.
Example: 250 A - 30% means working for 3 minutes at 250 A with
7 minutes rest time.
2 EN
PRIMARY
230 V
50 Hz
19,5 A
11,5 A
33 A
SECONDARY
18 ÷ 45 V
35 A ÷ 300 A
300 A
230 A
180 A
IP 23
H
Kg. 96
mm 620 x 940 x 1000
EN 60974.1 / EN 60974.10
PRIMARY
230 V
50 Hz
15 A
27 A
15,6 A
SECONDARY
18 ÷ 40 V
35 A ÷ 250 A
250 A
170 A
140 A
IP 23
H
Kg. 80
mm 500 x 870 x 950
EN 60974.1 / EN 60974.10
EN
400 V
19 A
400 V
8,5 A

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Blumig 283cBlumig 353cBlumig 253alu