The loading valve is required and must be
provided in the hydraulic system.
This operation must be carried out with caution
following these steps:
• open the vent's valve of the radiator ,of the
thermostove and the system;
• Gradually open the
checking that the automatic vent's valves, placed
on the system, are regularly working;
12
lling tap of the system
• Close the vent's valves of the radiators as soon as
the air ows out;
• check through the pressure gauge placed in the
system that the pressure is reaching 1 bar (this is
required only for systems with closed vase, you
have to look for local rules that allow it); whereas
for systems with open vase the restoration will be
automatic;
• Close the lling tap of the system and then let
the air ow out again through the vent's valve of
the radiator;